Mola Peg Anchor Fitting Guide

1. Locate nut at top of stud

2. Insert into hole, allowing slotted section to pass through hole 3. Strike pin home

4. Torque to ABS recommendations

16mm

Drill 16mm

ugh hole

g Anchor uide

nut at top of stud

to hole, allowing slotted section to pass through hole in home

to ABS recommendations

16mm

Drill 16mm

Mola Peg Anchor Fitting Guide

1. Locate nut at top of stud

2. Insert into hole, allowing slotted section to pass through hole 3. Strike pin home

4. Torque to ABS recommendations

Mola Peg Anchor Fitting Guide

1. Locate nut at top of stud

2. Insert into hole, allowing slotted section to pass through hole 3. Strike pin home

4. Torque to ABS recommendations

Recommended tensile safe working loadings for Peg Anchor stock diameters.

Recommended shear safe working loadings for Peg Anchor stock diameters.

Size Grade Finish Product

Code

Clamping Range Tensile

(KN)

Single Shear (KN)

Torque Min (mm) Max (mm)

M8 x 50 8.8 Zinc / Clear PA0850 5 34 20 22 20

M10 x 50 8.8 Zinc / Clear PA1050 5 30 32 30 35 M12 x 60 8.8 Zinc / Clear PA1260 7 36 49 49 50 M16 x 60 8.8 Zinc / Clear PA1660 7 32 75 75 100 M20 x 75 8.8 Zinc / Clear PA2075 7 35 110 120 125

Size Tensile (KN) Size Tensile (KN)

M8 4 M16 15.0 M10 6.4 M20 22.0 M12 9.8 M22 26.8 M14 12.6 M24 29.15

Size Shear (KN) Size Shear (KN)

M8 14.6 M16 50.2 M10 20 M20 80.4 M12 32.6 M22 102.3 M14 49.1 M24 147

MOLABOLT PEG ANCHOR – SOLviNG THE PROBLEM Of BLiNd APPLiCATiONS iN STEEL CONSTRuCTiON

1. Locate nut at top of stud 2. Insert into hole, allowing slotted section to pass through hole 3. Strike pin home 4. Torque to ABS recommendations.

Please Note: all SWL tensile fgures require a safety factor loading of 5:1 based on ultimate load results. Ultimate Load Testing has been carried out by independent UKAS accredited laboratories.

Please Note: all SWL shear fgures require a safety factor loading of 1.5:1 based on independent UKAS laboratory accredited test data.

Note: Care should be taken not to impact pin until bolt is fully home

Please Note: all SWL tensile fgures quoted above have an inbuilt safety factor loading of 5:1 based on ultimate load results. Ultimate Load Testing has been carried out by independent UKAS accredited laboratories.