« Previous Page Table of Contents Next Page »STANdARd HANd RAiL dETAiL
STANdARd STAiR RAiL dETAiL
edge ture
Mid rail must be halfway
Fasten stair rail at 1000mm in height
Maximum distance between posts 2.1m on centres
Top rail - 90x45 F7 or better
Mid rail - 90x45 F7 or better
Fasten stair rail at 1000mm in height
Top rail must be a minimum of 1000mm in height
Mid rail must be halfway between top rail and surface
UNPROTECTED SIDE OR EDGE
Stair rail must be 900mm in height
Stair rail must be 900mm in height
TOP RAIL - 90 x 45 F7 OR BETTER
MID RAIL - 90 x 45 F7 OR BETTER
TOE BOARD - 90 x 45 F7 OR BETTER
Maximum distance between posts 2.1m on centres
Maximum distance 450mm to centre of post 100mm clearance
Maximum distance 450mm to centre of top post
Top rail must be a minimum of 1000mm in height
Mid rail must be half way between top railing and surface
UNPROTECTED SIDE OR EDGE OF PERMANENT STRUCTURE
Leave room for plasterboard installation
If materials are brought through Guardrail System, lift out toeboards and only remove mid-rails.
Immediately replace when fnished.
Workers must use Personal Fall Arrest Systems if top railings are also removed.